Guide

Drying goal and dry standard

Short answer

Take a reading of the same material in an unaffected area with the same meter – that is the dry standard. Set the drying goal for each monitoring point from it. Equipment stays until every point meets its goal; the day it does is the documented end of drying.

Set the goal per material

Drywall, wood framing, subfloor and concrete read differently and different meters use different scales. Take the dry standard for each material type, with the same meter and scale you use on the wet side, and write both values down.

Monitoring points

Mark each point on the moisture map (room, material, location) and read the same points every day. A point that is still above goal is the reason equipment stays.

End of drying

Drying ends when every point meets its goal. Record the final reading set and the time equipment was removed – that day closes the equipment-day count.

Section numbers differ between editions of ANSI/IICRC S500, so this guide names the topic. Your copy of the current edition and your own professional judgment are the reference. This guide is general information, not legal advice. IICRC is a registered trademark of the Institute of Inspection, Cleaning and Restoration Certification. ANSI/IICRC S500 is the IICRC Standard for Professional Water Damage Restoration. Drypol is not affiliated with or endorsed by the IICRC; we cite the standard by topic and do not reproduce it.